specifications
-
Base Building
- Structure - RCC Structure
- Column Span - 8.4 mts.
- Cladding - Composite Aluminum Panels
Make: AlcoBond - Glazing - Make: Glaverbel (Super Silver clear glass)
Double Glazing
External (Laminated toughened) – 6mm
Internal (Clear annealed) – 5 mm - Floor Height - 3.75 mts.
- Floor to underside of slab - 3.55 mts.
- Typical - 400 KG/m2
- Critical - 1080 KG/m2
- No. of elevators - 04 (Each Tower)
- Capacity per elevator - 20 persons
- Weight capacity - 1.35 tons
- No. of elevators - 01 (Each Tower)
- Weight capacity - 1.5 tons
- CCTV - Yes
- Manned security desk - Yes
- Pantry - 2 nos. on each floor located within the service core
- Toilets Male - 2 nos. on each floor located within the service core
- Janitor Room - Located within the service core
- Floor Trunking - Mosaic sub floor shall be provided with an average thickness of 45 - 55 mm
- Sanctioned Power Load for the Development - 8 MVA
- Power load provision - 1.25 KVA/100 sq. ft. carpet area
- Generator Back-up - 100 % generator back-up provided
DG sets configuration (Blocks C, D & E: 725 KVA x 8 nos.) Make: Cummins - Type of HVAC system - VRV System of Air-conditioning
(Outdoor and Indoor units provided; installation to be done by client)
Make: Bluestar Sanyo
(Please refer to annexure to note on power savings associated with VRV System within Annexure-A) - Total AHU Capacity/ Tonnage on each floor - To be calculated as per client’s interior layout & load. Typically 1 Ton/ 175 Sq.ft. is considered.
- Design temperature inside - 23 + 1.5˚C.
- Relative Humidity - Less than 60%
- Ambient temperature - As per Pune Weather Data.
- Fibre-optic cables - Right Of Way provided to all providers
Dual route provision - No. of existing vendors(Names) - (4) BSNL, Tata Indicom, Reliance, Bharti
- Space for Satellite dish - Can be made available
- Fire Detectors & Sprinklers - Provided in all common areas
- Common Fire Tank Capacity - 300,000 litres
- Source - Pune Municipal Corporation
- Over head / Underground tank capacity - Over head tank capacity for each tower: 40,000 litres
Common underground tank capacity: 600,000 litres - Building sanction plans - Yes
- Title verification - Can be facilitated
- Private IT Park Registration - Yes
Floor Loading
Elevators
Service Elevators - Make: Fujitec
Security System
Female - 2 nos. on each floor located within the service core
Handicap - 1 no. on each floor located within the service core
Electrical Provisions
HVAC
Information Technology
Fire Protection/Fighting Systems - As per Pune Municipal Corporation/ NFPA norms
Water Supply
Legal